單項(xiàng)選擇題Badly leaking refrigeration compressor discharge valves will cause().

A.overfeeding of the expansion valve
B.damage to the condenser
C.constant running of the compressor
D.flooding of the receiver


您可能感興趣的試卷

你可能感興趣的試題

1.單項(xiàng)選擇題Mechanical energy in transition is referred to as ().

A.horsepower
B.work
C.heat
D.velocity

2.單項(xiàng)選擇題If you change from a low pour point lubricant to a high pour point lubricant in a refrigeration system, ().

A.compressor lubrication will be improved
B.oil will not leave the crankcase
C.compressor valves will be damaged
D.oil may congeal in the evaporator

3.單項(xiàng)選擇題When a vessel is in dry-dock, the vessel’s engineers should ().

A.examine the condition of the propeller
B.chip and paint all hull protection zincs
C.install new docking plugs in all cofferdams
D.inspect the hull for hogging or sagging

4.單項(xiàng)選擇題Air line lubricators are used in compressed air systems to lubricate ().

A.the suction and discharge valves
B.tools and equipment served by compressed air
C.air line reducing valves
D.all of the above

5.單項(xiàng)選擇題Which of the listed devices would be installed at a control system air pressure reducing station?()

A.Moisture separator
B.Vacuum breaker
C.Lubricator
D.Non-return valve

最新試題

Thermostatic expansion valves can be adjusted for ().

題型:單項(xiàng)選擇題

The major source of chemical contaminants in hydraulic fluid is ().

題型:單項(xiàng)選擇題

The temperature differential occurring between the inlet temperature of the fluid to be cooled and the outlet temperature of the cooling medium in a shell-and-tube heat exchanger is greatest in which of the flow designs listed?()

題型:單項(xiàng)選擇題

An internal bypass is provided on some hydraulic system suction strainers to help reduce the possibility of ().

題型:單項(xiàng)選擇題

Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()

題型:單項(xiàng)選擇題

If you are given the job of adding hydraulic fluid to a mooring winch, and are not certain as to the type of fluid to use, you should ().

題型:單項(xiàng)選擇題

An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().

題型:單項(xiàng)選擇題

If the viscosity of the liquid being transferred remains constant as the discharge pressure increases, the rotary pump ().

題型:單項(xiàng)選擇題

When a refrigeration compressor has developed a high head pressure as a result of a refrigerant overcharge, you should ().

題型:單項(xiàng)選擇題

When the steering gear is in operation, you should ().

題型:單項(xiàng)選擇題