單項選擇題As an alternative to the conventional seawater cooling system, is based on principles about cooler locations, ()flow control and preheating, but with a central cooler and one additional set of pumps().

A.the central cooling system, different
B.the central cooling system, the same
C.the open cooling system, different
D.the open cooling system, the same


您可能感興趣的試卷

你可能感興趣的試題

1.單項選擇題()is harmful for fuel pumps, fuel valves, cylinder liner, exhaust valve seats, and the turbocharger blades as well.

A.Bad combustion of the fuel
B.Bad atomization of the fuel
C.Liquid contaminants
D.Solid contaminants

2.單項選擇題The booster pump, which supplies diesel oil to() , should have a possibility of being powered by compressed air or by emergency power.

A.the main engines
B.the auxiliary engines
C.the emergency generator engine
D.the auxiliary engines and the main engine(s)

3.單項選擇題A full-flow 50μm filter is installed ,() so the injection system components on the main engine are safeguarded.

A.as close to the main engine as possible
B.as close to the main pump as possible
C.just before the fuel valve
D.just before the booster pump

4.單項選擇題The fuel from the bunker tanks must be treated by before entering the service tanks(), from where the fuel enters()

A.centrifugal separators; the engine cylinder
B.oily water separators; the engine cylinder
C.oily water separators; the fuel supply system
D.centrifuges; the fuel supply system

5.單項選擇題When the heavy fuel oil is heated to achieve the viscosity of 10-15 cst, may occur.To avoid this, a system is used in most occasions()

A.boiling and cavitations; low temperature
B.boiling and cavitations; pressurized
C.leaking and boiling; low temperature
D.leaking and boiling; pressurized