A. Server
B. End device
C. Node
D. Host
E. Virtual
您可能感興趣的試卷
你可能感興趣的試題
A. Sending all broadcasts
B. Receiving all traffic from upstream switches
C. Receiving broadcast traffic
D. Negotiating spanning tree with upstream switches
E. Learning MAC addresses from upstream switches
A. The Cisco VIC can create an unlimited number of Virtual NICs
B. The number of vNICs on the Cisco VIC that can be created is determined by the number of chassis uplinks
C. vNICs are created using software on the host operating system
D. The host operating system sees a vNIC as a physical PCIe device
E. The host operating system sees a vNIC as a sub-interface of a primary NIC
F. The Cisco VIC can create 1024 vNICs
A. Fibre Channel storage
B. UCS C-Series servers
C. NFS storage
D. UCS chassis
E. Other fabric interconnect
A. End-host mode is synonymous with NPV mode.
B. In end-host mode, only hard pinning of vHBAs to Fibre Channel uplink ports is allowed.
C. Making configuration changes between Fibre Channel switching mode and end-host mode is nondisruptive.
D. End-host mode is the default Fibre Channel switching mode.
A. In the blade BIOS
B. In the operating system
C. In the service profile
D. In the card option ROM
最新試題
What interface is created when an FC Port Channel is created on a Cisco Unified Computing System?()
In a Cisco Unified Computing System, where are SAN port channels connected to?()
When testing ICMP access to a functional load-balancing ACE VIP, it fails. What is the reason of this problem? ()
What would be the cause for the following fault in UCS Manager?() "ether VIF x / xxx down, reason: ENM source pinning failed"
Application Control Engine (ACE) can check the health of servers and server farms by configuring health probes (which are sometimes referred to as keepalives). A probe can be one of many types. Which are valid ACE probes? ()
What is the appliance port used to connect to in a Cisco Unified Computing System?()
An administrator is creating a service profile but receives an error when applying to a blade. The administrator checks the faults tab of the service profile and finds the following error (Refer to the exhibit).What is the cause of this error?()
Your company wants Server 1/eth0 (vNIC 1) configured so that it always uses Fabric Interconnect A Port Channel 1 (Po1) when it communicates with anything outside of the Cisco UCS domain. However, if vNIC 1 fails over to Fabric Interconnect B using fabric failover, then vNIC 1 can any uplink port on Fabric Interconnect B. Which statements are true? ()
Refer to the exhibit.The Cisco UCS domain is operating in switching mode. A network administrator notices that no traffic is traversing the uplinks on Fabric Interconnect B (Path C). Which actions might be used to change this behavior?()
Given a Cisco Unified Computing System, which is a valid port type in end-host mode?()