單項(xiàng)選擇題One cause of high head pressure occurring in a refrigeration system can be ().

A.insufficient cooling water flow to the condenser
B.a low refrigerant charge in the system
C.the liquid valve is open too much
D.high evaporator superheat


您可能感興趣的試卷

你可能感興趣的試題

1.單項(xiàng)選擇題The control mode in which the final control element is moved from one of two flexed positions to the other is known as ().

A.dead band action
B.neutral zone action
C.range
D.on-off action

2.單項(xiàng)選擇題Pitting in the suction areas of a centrifugal pump bronze impeller is usually caused by ().

A.cavitation
B.electrolysis
C.abrasion
D.corrosion

3.單項(xiàng)選擇題If the head pressure of a reciprocating refrigeration compressor is excessive, ().

A.the relief valve should open before the high pressure cutout
B.the relief valve should open and allow the excess refrigerant to flow to the receiver
C.the high pressure cutout switch should operate before the relief valve opens
D.you should close in on the suction valve

4.單項(xiàng)選擇題A salinity indicator is used to determine the ().

A.cause of salt contamination
B.location of salt water contamination
C.chemical makeup of feed-water
D.level of alkalinity in condensate

5.單項(xiàng)選擇題An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().

A.restriction in refrigerant piping
B.air and non-condensable gases in the condenser
C.water in the refrigerant
D.flooding back of liquid refrigerant from the evaporator

最新試題

If the viscosity of the liquid being transferred remains constant as the discharge pressure increases, the rotary pump ().

題型:?jiǎn)雾?xiàng)選擇題

Pitting in the suction areas of a centrifugal pump bronze impeller is usually caused by ().

題型:?jiǎn)雾?xiàng)選擇題

An excessive charge of refrigerant in an air-cooled refrigeration system can cause ().

題型:?jiǎn)雾?xiàng)選擇題

The control mode in which the final control element is moved from one of two flexed positions to the other is known as ().

題型:?jiǎn)雾?xiàng)選擇題

The temperature differential occurring between the inlet temperature of the fluid to be cooled and the outlet temperature of the cooling medium in a shell-and-tube heat exchanger is greatest in which of the flow designs listed?()

題型:?jiǎn)雾?xiàng)選擇題

On tank vessels equipped with power operated cargo tank valves, the type of power operator most commonly used is ().

題型:?jiǎn)雾?xiàng)選擇題

Which of the problems listed would came the discharge temperature of an R-12 refrigeration compressor to increase?()

題型:?jiǎn)雾?xiàng)選擇題

An increasing head pressure in a refrigeration system, without any corresponding change in the cooling water inlet temperature, would probably be caused by ().

題型:?jiǎn)雾?xiàng)選擇題

Which of the listed pumps is NOT a positive displacement pump?()

題型:?jiǎn)雾?xiàng)選擇題

If you are given the job of adding hydraulic fluid to a mooring winch, and are not certain as to the type of fluid to use, you should ().

題型:?jiǎn)雾?xiàng)選擇題